A bolt can experience a change in tensile force every time the equipment starts or stops. Fatigue cracks often begin at the first fully engaged thread, inside the nut near the face that bears on the clamped part. Following the load from the bolt shank into the nut and looking at the test fractures explains why this location deserves attention.
Counting from the bearing face of the nut
In an axial section through a bolt joining two parts, the head is at one end and the nut at the other. The face of the nut against the part or washer is its bearing face. From there, look toward the bolt end for the first complete turn of external thread that engages the nut. The entry chamfer can leave a short distance between the bearing face and the first complete thread profile. [1]
Visually, counting from the outside is convenient—only the threads exposed on the nut side are visible, with no matching internal threads. To determine where load transmission begins, shift focus to the nut's entry near the workpiece and identify the first complete thread engagement. The thread end transitioning to a smooth shank is a common point of confusion. Label this as the thread termination, and mark the first fully engaged thread inside the nut in the cross-section. This alignment helps match crack initiation with fracture surface observations later. [2]
For the same bolt with sufficient thread length, if assembly changes the nut's axial position, the first fully engaged thread may shift to a different turn on the bolt shank. Research reports often describe crack initiation based on the nut's bearing face because of this. When examining a disassembled specimen, knowing where the nut originally pressed and where it stopped is part of interpreting the test records. [1]
The threads near the bearing face transfer load first
After tightening, the bolt shank elongates and the nut clamps the workpiece. Axial tension travels along the thread flanks from the bolt toward the nut, then through the bearing face back to the workpiece. Mentally slice through this path several times. Before reaching the engaged zone, all load remains on the bolt. Once past one engaged thread turn, the axial force in the bolt shank decreases by the portion transferred to that turn. The sum of forces transmitted through each turn equals the total axial load taken by the nut. [2]
Why do the turns rarely take equal shares? The bolt stretches in tension, while the nut transfers force back into the parts through its bearing face. Internal and external threads undergo different axial deflections, and the individual turns also deform. Initial flank clearance and the way the flanks bear against each other under load determine the share transferred by each turn. A University of Texas report compares models with matching and differing thread pitches. The matching-pitch model shows a higher load near the bearing end. Changes in fit or nut stiffness shift the distribution. [2]
Thus, seeing several complete threads engaged in the nut only indicates which teeth may participate in load transfer. Each additional thread provides another load-bearing position; teeth near the bearing face may still carry a significant share. The load on the first thread cannot be deduced from nut height or total thread count alone. When tracking the first engaged thread, one must identify the bearing face. To explain the loading on the first thread, one must examine how the thread profiles interact and deform. [2]
Contact loads the flank and stress concentrates at the root
Enlarging a single external thread, the crest is the raised portion, the sides are the flank, and the base connecting to the adjacent groove is the root. The bolt and nut transfer load through flank contact. The contact force acts on the raised tooth, then passes through the root region into the bolt shank. Simultaneously, the existing axial tensile force in the shank also passes through this region. Thus, the root of the first thread experiences two loading effects: first, the shank still carries a large tensile load; second, this thread is transmitting a significant portion of the applied load to the nut. [2]
Comparing a smooth rod with a threaded shank reveals why the root is particularly sensitive. In ideal axial tension, a smooth rod has relatively uniform stress across sections away from the loading end. In the threaded region, the root narrows the local cross-section, and the arc connects to the inclined flank, causing a redistribution of force. Dividing the tensile load by the selected cross-sectional area yields a nominal stress. However, the peak stress near the root surface is additionally influenced by the root radius and the contact load transfer through the flank. [3]
Fukuoka and his colleagues treated the thread-root fillet and friction at the contact surfaces as variables in their contact analysis. For a given tensile load, the stress in a small region depends on both the thread profile and the fit. During repeated loading, stress in a small region of the root surface can vary more than a shank-level estimate suggests. A crack can start at that local surface and grow into the section over successive cycles. [3] [1]
How much stress variation does the thread root experience per load cycle?
The joined components and the bolt can be modeled as an elastic system. At assembly, the bolt has preload and the components have clamping force. During operation, external loads pull the components apart; as long as the interface remains closed, bolt tension increases and clamping force decreases. The magnitude of these changes together corresponds to the applied external load. The stiffness of the bolt, the compressive stiffness of the components, and the location of external load application determine how much each component contributes. [4]
Axial tension example
Assume initial preload is 20 kN, and the interface remains closed. At a selected loading position, 20% of the additional external load converts into bolt tension increase. When external load rises from 0 to 5 kN, 1 kN is added to the bolt, increasing its tension from 20 kN to 21 kN. The remaining 4 kN reduces the clamping force from 20 kN to 16 kN. The difference between the two forces exactly equals the applied 5 kN. In this ideal elastic model, removing the external load restores both forces to their original values. The 20% is a hypothetical ratio introduced to illustrate the relationship.
In each cycle the external load varies over 5 kN, while bolt tension fluctuates between 20 and 21 kN. The bolt tension range is 1 kN, its amplitude is half that range, or 0.5 kN, and its mean is 20.5 kN. The bolt remains in tension throughout, yet the variation reaches the thread root. A fatigue analysis must estimate the resulting local stress range. Static tensile capacity and life under repeated loading are measured by different tests. [1] [4]
As the clamping force declines to zero and the joint interface fully separates, the load path changes. In this simplified axial model, any further increase in external load is carried essentially by the bolt. The same external load range can therefore produce a different bolt tension range in a joint that remains closed and in one that opens each cycle. To interpret a fatigue test or service record, track both the applied loading and whether the joint remained clamped. [4]
Observing crack initiation and final fracture locations from test records
The axial fatigue study of anchor bolts at the University of Texas at Austin subjected specimens to repeated tensile loading. Since the nut interior could not be directly observed, researchers intermittently used ultrasonic methods to detect crack signals during loading, and finally examined fracture surfaces or cross-sectioned specimens. The report documented 42 tests, of which 16 showed crack indications during loading. This number reflects how many times process evidence was recorded; whether cracks were visible in the remaining tests depends on detection timing and conditions. [1]
Among the series with in-test observations, cracks leading to fracture started at the first fully engaged thread near the nut bearing face in most series. One series provided an exception. In several of its specimens, cracks were first detected about two thirds of the way through the nut, measured from its bearing face. Sections through failed ends revealed multiple cracks within the nut. Final fracture still occurred near the first thread. The earliest detected crack and the one that ultimately caused fracture can be separate cracks. [1] [2]
The fracture surface provides evidence of crack propagation. In some specimens, cracks initially grow from the outer surface inward, then expand circumferentially and radially. As the remaining cross-section shrinks, the same axial load is carried by less material. Eventually, during a loading cycle, the reduced cross-section fails. Observing the final fracture surface reveals a path from surface to interior, allowing identification of crack origin and differentiation between crack propagation zones and the final fracture zone. [1]
Reviewing a bolt fractured near the nut allows overlaying the bearing face, the first fully engaged thread, and crack initiation signs on a single cross-sectional diagram. This is then compared with known assembly and loading history. The first thread warrants special attention because axial load transfers from bolt to nut here, and the thread root is a region of abrupt cross-section and contour change. The actual crack initiation point must be confirmed by fracture surface evidence. [1] [2]
Technical basis
- Fischer & Frank (1977), 172-1, §1.1, §2.6, §3.1.1, §3.2, Figs. 11–13. axial tension fatigue test of anchor bolts
- Frank (1978), 172-2F, §3.1, Figs. 8–11. fatigue of anchor bolts and thread loading distribution
- Fukuoka et al. (1986), Japan Society of Mechanical Engineers. thread root fillet, friction, and stress concentration
- Chambers (1995), NASA TM-106943, Figs. 4, 6, 12. analysis methods for preloaded bolted joints